Resistive-Reactive Loadbanks
A Resistive-Reactive Loadbank allows testing at conditions replicating a lagging power factor and ensures complete engine and alternator testing. Many Generators and Turbines are rated at around 0.8pf and therefore can only be fully tested at 100% nameplate rating by utilizing a Resistive-Reactive loadbank. Crestchic offers both Combined Resistive-Reactive or Reactive only Loadbanks.

Crestchic design and manufacture a wide range of fixed or variable power factor Resistive-Reactive Loadbanks in standard frames sizes & containers, from 50kVA to 6250kVA, built to your specific voltage, frequency and phase requirements. All our loadbanks employ stainless steel finned elements for maximum heat dissipation and durability.
- Reactive (Inductive) only loadbanks available
- Typical power factor 0.8
- Voltage from 110v to 690v
- 50 – 60 HZ
- 50kVA to 6250kVA
- NEMA Type 4/ IP55 standard protection
- Standard canopy sizes to 300kVA
- Container packages for 375kVA and above
- Multiple 1kVA load steps
- Stainless steel finned elements
- Choice of control system for all units – suited to application & operators
- Ambient temperature operation to 45°C
- Built in the UK to a high industrial standard, all manufacturing processes are BS EN ISO 9001 2008 certified
Resistive-Reactive Loadbanks Specifications:
50kVA | 75kVA | 100kVA | 125kVA | 150kVA | 200kVA | 250kVA | 300kVA+ | |
---|---|---|---|---|---|---|---|---|
Spec Sheet Downloads | 300kVA | |||||||
Power Range | 50 kVA (40kW @ 0.8pf) 380/480 volts, 50/60 Hz | 75 kVA (60kW @ 0.8pf) 380/480 volts, 50/60 Hz | 100 kVA (80kW @ 0.8pf) 380/480 volts, 50/60 Hz | 125 kVA (100kW @ 0.8pf) 380/480 volts, 50/60 Hz | 150 kVA (120kW @ 0.8pf) 380/480 volts, 50/60 Hz | 200 kVA (160kW @ 0.8pf) 380/480 volts, 50/60 Hz | 250 kVA (200kW @ 0.8pf) 380/480 volts, 50/60 Hz | 300 kVA (240kW @ 0.8pf) 380/480 volts, 50/60 Hz |
Footprint | 40'' x 34'' Enclosure | 40'' x 34'' Enclosure | 40'' x 34'' Enclosure | 40'' x 34'' Enclosure | 60'' x 40'' Enclosure | 60'' x 40'' Enclosure | 60'' x 40'' Enclosure | 60'' x 40'' Enclosure |
Design Voltage | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order |
Minimum Load Steps | 1kW / 1kVA | 1kW / 1kVA | 1kW / 1kVA | 1kW / 1kVA | 1kW / 1kVA | 1kW / 1kVA | 1kW / 1kVA | 1kW / 1kVA |
Control Systems | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation |
Ambient Parameters | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity |
Fan and Control Power | Via main bus, or ## external source | Via main bus, or ## external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source |
Air Flow | Horizontal | Horizontal | Horizontal | Horizontal | Horizontal | Horizontal | Horizontal | Horizontal |
Enclosures | Weatherproof Enclosure | Weatherproof Enclosure | Weatherproof Enclosure | Weatherproof Enclosure | Weatherproof Enclosure | Weatherproof Enclosure | Weatherproof Enclosure | Weatherproof Enclosure |
Dimensions | Height: 54'' Width: 34'' Length: 40'' Weight: 1,040 lbs | Height: 54'' Width: 34'' Length: 40'' Weight: 1,235 lbs | Height: 54'' Width: 34'' Length: 40'' Weight: 1,370 lbs | Height: 54'' Width: 34'' Length: 40'' Weight: 1,575 lbs | Height: 62.0'' Width: 40.0'' Length: 60.0'' Weight: 2,200 lbs | Height: 62.0'' Width: 40.0'' Length: 60.0'' Weight: 2,645 lbs | Height: 62.0'' Width: 40.0'' Length: 60.0'' Weight: 3,090 lbs | Height: 62.0'' Width: 40.0'' Length: 60.0'' Weight: 3,530 lbs |
375 - 500 kVA | 750 - 1000 kVA | 1250kVA | 1650kVA to 1875kVA | 2000kVA to 3300kVA | 3750kVA to 6250kVA | |
---|---|---|---|---|---|---|
Spec Sheet Downloads | 375-500kVA | 750-1000kVA | 1250kVA | 1500-1875kVA | 2000-3300kVA | 3500-4000kVA4375-5000kVA5500-6250kVA |
Power Range (kW @ pf) | 300 - 400kW @ 0.8pf - 50/60Hz | 600 - 800kW @ 0.8pf - 50/60Hz | 1000kW @ 0.8pf - 50/60Hz | 1200 - 1500kW @ 0.8pf - 50/60Hz | 1600 - 2640kW @ 0.8pf - 50/60Hz | 2800 - 5000kW @ 0.8pf - 50/60Hz |
Power Range (kVA) | 375 - 500kVA @ 380/480 volts, 50/60 Hz | 1000 kVA @ 380/480 volts, 50/60 Hz | 1250 kVA @ 380/480 volts, 50/60 Hz | 1650 - 1875 kVA @ 380/480 volts, 50/60 Hz | 2000 - 3300 kVA @ 380/480 volts, 50/60 Hz | 3750 - 6250 kVA @ 380/480 volts, 50/60 Hz |
Footprint | 5' x 4' Enclosure | 8' x 4' Enclosure | 10.5' x 4' Enclosure | 6' x 8' Enclosure | 10' x 8' Enclosure | 20' x 8' Enclosure |
Design Voltage | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order | Units can be designed at any voltage made to order |
Minimum Load Steps | 1.66kW / 1.96kVAR | 1.66kW / 1.96kVAR | 1.66kW / 1.96kVAR | 1.66kW / 1.96kVAR | 1.66kW / 1.96kVAR | 1.66kW / 1.96kVAR |
Control Systems | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation | Controlled via toggle switch, KCS manual, hand held controller, or PC with printed documentation |
Ambient Parameters | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity | Maintains maximum capacity in ambient conditions up to 120 F, and 100% humidity |
Fan and Control Power | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source | Via main bus, or ## amp, 480 volt, 3 phase external source |
Air Flow | Vertical | Vertical | Vertical | Vertical | Vertical | Vertical |
Enclosures | Weatherproof Container | Weatherproof Container | Weatherproof Container | Weatherproof Container | Weatherproof Container | Weatherproof Container |
Dimensions | Height: 7.6' Width: 4.0' Length: 5.0' Weight: upto 5,730 lbs | Height: 8.0' Width: 4.0' Length: 8.0' Weight: upto 8,400 lbs | Height: 7.5' Width: 4.0' Length: 10.5' Weight: 10,000 lbs | Height: 8.5' Width: 8.0' Length: 6.2' Weight: upto 13,300 lbs | Height: 8.5' Width: 8.0' Length: 10.0' Weight: upto 22,050 lbs | Height: 8.5' Width: 8' Length: 20.0' Weight: upto 38,580 lbs |